CIL R

CIL from R series

R... / RS... - Tube Fans
Construction of steel and plastic

 

  • easy installation in any position
  • easy electrical connection via terminal box
  • motor protection by thermal contacts
  • isolation class F


_____________________________________________________________________________________________________

Description:

Tube fans represent  a technically  perfect solution,  uniting  the  advantages  of  axial fans,  straight airflo w  and easy installation, with high pressure stability, low noise level and high efficiency of the radial fans.


Application areas:
Garage / Offices / Bars / Greenhouses / Skyscrapers / Hotels / Industrial buildings /  Basement rooms /  Playschool / Cinemas / Parking facilities / Warehouses /  Nursing homes /  Schools / Sports halls /  Supermarkets /  Workshops / Residential houses / Fitness centers / Inflatables

Reference to Directives:
 Declaration of incorporation and operating instruction are according to Machinery Directive 2006/42/EC, CE identification in  accordance to EMC-Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and the Ecodesign-Directive 2009/125/EC.
____________________________________________________________________________________________________

Casing:

Steel type (R)
The casings are manufactured of galvanized sheet steel

Plastic type (RS)
The  casings are  equipped  with  an attractive and  hardly  inflammable plastic  casing with integrated  
IP44  terminal box and guide vane.


Advantages of the plastic types compared to sheet steel types:

  •  lower noise level
  •  completely corrosion resistant
  •  easy installation with mounting brackets
  •  higher pressure and better efficiency through guide vane


_____________________________________________________________________________________________________

Impellers:

The impellers are balanced together with the external rotor motors at two  levels  according to quality level G2.5 to DIN 1940.

Type R:
100-250      = backward curved centrifugal impeller made of plastic
250L-315M  = backward curved centrifugal impeller made of galvanized sheet steel
from 355     = backward curved centrifugal impeller made of aluminium

Type RS:
100-250L   =  backward curved centrifugal impeller made of plastic
from 315    =  backward curved centrifugal impeller made of galvanized sheet steel

_____________________________________________________________________________________________________

Motor and motor protection:

All Rosenberg fans are  equipped with  direct driven  external rotor motors.  All our fans have motor protection  through thermal contacts in the motor windings as standard. The motors apply to protection class IP44/IP54.


The drive has due to an external rotor motor a space saving, compact and attractive design. The motor is fitted within the impeller, which enables the best possible cooling. For this reason  a  100%  variable speed control can be guaranteed. V-belts, additional tension bars and motor mounting devices are  not necessary.  Only well-dimensions ball-bearings,  fitted on both sides and  life  time  greased are  used.
Both ball-bearing seats are  ground to high  precision in one work process to eliminate  any  vibrations.
External rotor motors have extremely low starting currents.  The windings  comply to  isolation class F.
In addition the windings have a standard moisture impregnation.

_____________________________________________________________________________________________________

Electrical connection:

Series R:
The electrical connection is mounted on the housing by a terminal box with IP54 protection.

Series RS:
The electrical connection is mounted on the housing by a terminal box with IP44 protection.

_____________________________________________________________________________________________________

Installation:

Rigid folded spiral-seam ducts (Spiro),  flexible aluminium or plastic ducts with standardized diameter can be used.

_____________________________________________________________________________________________________

Air volume control:
For more information see accessories!
       
5-speed control
230V  à   RE / RTE
400V  à   RTD

Infinietly variable control (except R355L)
230V  à ED

_____________________________________________________________________________________________________

Scope of delivery:

Type R:
  Tube fan (R)
  Foot (inclusive only for R400L E/D)
  Documentation

Type RS:
  Tube fan (RS)
  Mounting bracket
  Documentation

_____________________________________________________________________________________________________

Important notes:

Air performance curves:
The performance curves for these fan types have been measured in mounting position D (installed on the pressure side and open on the suction side)  and  show  the  total  pressure  increase ∆pt as a function of the air flow.  The  dynamic pressure ∆pd2 refers to the flange cross section at the outlet side of the fan.  

Noise levels:
The bordered values printed in the performance curve diagrams show the "A"  weighted LWA6 sound power level at the outlet side in duct systems. The relative octave sound power level LWArel at octave medium frequency you can find on type page.

Classification of the fan series:
NRVU    = Non Residential Ventilation Units
UVU    = Unidirectional Ventilation Units

Erp-Information:
Rosenberg fans have a spezfic (pressure-) ratio < 1,05 (pressure < 5000 Pa).

Service life:
For maximum service life of Rosenberg products please beware of the maintenance hints on the manual for each product type.

Recycling and disposal:
For recycling and disposal of Rosenberg products comply with applicable locally requirements and regulations.

Tube fans with casing made of galvenized sheet steel

Casing of the R-series made from galvanized sheet steel (R 355 L STAHL, R 355 M.5FA, R 355 STAHL, R 400 LE STAHL made of aluminium). Electrical connection via terminal box fitted to the outside. Inlet and outlet side with duct connection for standard round ducts can be mounted in any position. Both ranges with backward curved impellers made from plastic, size 355 L made from aluminium and with speed controllable external rotor motor, fitted into the impeller. The fans are balanced according to quality level G 2.5, DIN/ISO 1940 on two levels. Motor closed, protection class IP 44/54, with thermal contacts, wired in series in motor windings from size R 355 L. Maintenance free ball bearings, closed on both sides, sealed for life.

Reference to Directives:
Declaration of incorporation and operating instruction are according to Machinery Directive 2006/42/EC, CE identification in accordance to EMC-Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and the Ecodesign-Directive 2009/125/EC.

For further information, please click the model below for detail.

R 100 L STAHL R 150 STAHL R 250 L STAHL R 315 STAHL R 400 LD STAHL
R 100 STAHL R 160 L STAHL R 250 L.3DF R 315.3EF R 400 LE STAHL
R 125 L STAHL R 160 STAHL R 250 STAHL R 355 L STAHL  
R 125 STAHL R 200 L STAHL R 315 L STAHL R 355 M.5FA  
R 150 L STAHL R 200 STAHL R 315 M.3EF R 355 STAHL  

 

Picture of CIL from R 100 to R 315

 

Picture of R 400 LD STAHL and R 400 LE STAHL